• WEINVIEW触摸屏在太阳能光伏并网逆变器中的应用———WEINVIEW触摸屏在太阳能光伏并网逆变器中的应用
    威纶通科技有限公司

    Abstract:In recent years, with the large number of solar photovoltaic power plants establishing and grid connection generation at home and abroad , As the key equipment in PV power generation, photovoltaic grid-connected inverter has broad market prospect. The introduction in this paper focus on the application of WEINVIEW touch screen in photovoltaic grid-connected inverter. In this system, touch screen communicates with the microcontroller, and completes related data acquisition, information saving, alarm information loginning, and shows operating parameters and real-time status of inverter on the touch screen , Remote communication with the host computer through the RS485 or the Ethernet, At last to achieve real-time monitoring and deploy of the entire grid station.

    Keywords: Photovoltaic  Inverter  Touch screen    DSP

     

    一:引言

        随着全球气候变暖,传统的燃料资源日趋枯竭,世界各国都把目光投向了可再生能源,希望可再生能源改变人类的能源结构,维持长远的可持续发展。在可再生能源中,太阳能以其独有的优势而成为人们关注的焦点。太阳能是取之不尽、用之不竭、无污染的绿色能源。世界各国都在投入巨资建设大规模的太阳能发电站。我国在光伏研究和产业方面也取得了较快的进展,2006年1月1日实施的《可再生能源法》,标志着太阳能发电已纳入我国的能源发展规划之中。根据2007年9月发布的《可再生能源中长期发展规划》,2020年,我国太阳能发电设备累计装机容量将达到2000MW 。

        太阳能光伏并网逆变器是整个光伏发电系统中最为关键的设备之一,它是把太阳能电池板产生的直流电能转换为交流电能的设备,运行过程中需要多个参数进行监测、计算、显示、记录、保存、报警等处理,需要和上位计算机、逆变控制器进行通讯,实现数据交换。本文主要讲述WEINVIEW触摸屏在太阳能光伏并网逆变器中的应用。

    二:系统原理和方案设计

        太阳能光伏并网逆变器是把太阳能电池板通过光伏效应产生的直流电能进行逆变,转换成同电网同频率、同相位的交流电,接入电网对外进行输电。逆变器运行中要把测量的实时参数送给触摸屏,进行显示、记录等操作,也可和上位机通讯进行远程监控功能。系统原理图如下图所示:

    三:WEINVIEW画面设计要求

        本系统采用WEINVIEW MT8010IV2型号触摸屏,高品质10”宽屏设计,LED背光模组,采用400MHz RISC CPU,使运行速度更快,内置电源隔离保护器,提高了产品的抗干扰能力,适应复杂环境下运行。多种标准的通讯接口和网络协议,方便用户使用。大容量的数据存储功能,外接USB闪存和SD卡存储资料,满足逆变器运行过程中产生的海量数据信息。

        1,触摸屏主界面设计

        主界面显示逆变器运行的各种运行参数:PV电压、PV电流、A、B、C三项交流电压和电流、功率因数、电网频率、输出功率、日发电量、总发电量、CO2减排量等,逆变器运行状态指示,实时时间,以及其他操作菜单。下图分别是主界面的中英文显示菜单。

            2,功率曲线显示功能设计

        逆变器运行中实时功率是一个非常重要的参数,功率曲线图反映逆变器运行的历史运行情况和趋势。逆变器功率曲线显示由三条宏指令完成:

        A:逆变器运行的实时功率计算
        B:实时功率的RW_A保存
        C:功率曲线显示

        实时功率计算宏指令如下:

        macro_command main()
        short i,v
        int pa,pb,pc
        GetData(v, "Local HMI", LW, 2, 1)   //A相电压
        GetData(i, "Local HMI", LW, 3, 1)   //A相电流
        pa=v
        pa=pa*i                             //相乘   
        GetData(v,"Local HMI", LW, 4, 1)   //B相电压
        GetData(i,"Local HMI", LW, 5, 1)   //B相电流
        pb=v
        pb=pb*i                             //相乘
        GetData(v, "Local HMI", LW, 6, 1)   //C相电压
        GetData(i, "Local HMI", LW, 7, 1)   //C相电流   
        pc=v
        pc=pc*i                             //相乘
        pc=pa+pb+pc                         //A相B相C相功率之和
        SetData(pc, "Local HMI", LW, 300, 1)//存储在LW300中
        end macro_command

        功率计算宏指令1秒钟循环执行一次,把三相输出功率之和保存在LW300单元中。

        功率存储宏指令如下:

        macro_command main()
        short day,hour,minute
        int add,x
        GetData(minute, "Local HMI", LW, 9018, 1)   //读取分
        GetData(hour, "Local HMI", LW, 9019, 1)     //读取时
        GetData(day, "Local HMI", LW, 9020, 1)      //读取日
        add=day*1440+hour*60+minute             &nbs

     
     