• MINMAX模块电源MAU202
  • 价格:面议
  • 品牌:未填写
  • 产品简介:
  • 1W, High Isolation SIP, Single Dual Output DC/DC ConvertersKey Features‧ Efficiency up to 81%‧ 3000VDC Isolation‧ MTBF 2,000,000 Hours‧ Low Cost‧ Input 5, 12 and 24VDC&

    产品详情商家联系电话:86-0756-2219836

    1W, High Isolation SIP, Single & Dual Output DC/DC Converters
    Key Features
    ‧ Efficiency up to 81%
    ‧ 3000VDC Isolation
    ‧ MTBF > 2,000,000 Hours
    ‧ Low Cost
    ‧ Input 5, 12 and 24VDC
    ‧ Output 3.3, 5, 9, 12, 15, ±5, ±9, ±12 and ±15VDC
    ‧ Temperature Performance -40°C to +85°C
    ‧ UL 94V-0 Package Material
    ‧ Internal SMD Construction
    ‧ Industry Standard Pinout
     
      Selection Guide
    Model Number Input Voltage Output Voltage Output Current Efficiency Load Regulation
    VDC VDC mA % Typ. % Max.
    MAU201

    5
    ( 4.5 – 5.5 )

    3.3 260 73 10
    MAU202 5 200 71 10
    MAU203 9 110 76 8
    MAU204 12 84 78 7
    MAU205 15 67 78 7
    MAU206 ±5 ±100 72 10
    MAU207 ±9 ±56 77 8
    MAU208 ±12 ±42 78 7
    MAU209 ±15 ±34 79 7
    MAU211

    12
    ( 10.8 – 13.2 )

    3.3 260 74 8
    MAU212 5 200 73 8
    MAU213 9 110 78 5
    MAU214 12 84 80 5
    MAU215 15 67 80 5
    MAU216 ±5 ±100 74 8
    MAU217 ±9 ±56 79 5
    MAU218 ±12 ±42 81 5
    MAU219 ±15 ±34 81 5
    MAU221

    24
    ( 21.6 – 26.4 )

    3.3 260 73 8
    MAU222 5 200 71 8
    MAU223 9 110 76 5
    MAU224 12 84 78 5
    MAU225 15 67 79 5
    MAU226 ±5 ±100 72 8
    MAU227 ±9 ±56 76 5
    MAU228 ±12 ±42 79 5
    MAU229 ±15 ±34 80 5
     
     
     
     
     
    Minmax's MAU200 1W DC/DC's
    are specially designed to provide
    high levels of isolation 3000VDC
    in a miniature SIP package.

    The series consists of 27 models
    with input voltages of 5V, 12V and
    24VDC which offers standard output
    voltages of 3.3V, 5V, 9V, 12V, 15V,
    ±5V, ±9V, ±12V and ±15VDC for a
    wide choice.

    The MAU200 series is an excellent
    selection for a variety of applications
    including distributed power systems,
    mixed analog/digital subsystems,
    portable test equipments, local power
    networks and battery backed systems.

     

    Mechanical Dimensions
    Pin Connections
     
    Pin Singles Duals
    1 +Vin +Vin
    2 -Vin -Vin
    5 -Vout -Vout
    6 No Pin Common
    7 +Vout +Vout
    Case Size –
    5V & 12V Input – 19.5x6.1x10.2mm
    (0.77x0.24x0.40inch)
    24V Input –19.5x7.1x10.2mm
    (0.77x0.28x0.40inch)
    Case Material –
    Non-Conductive Black Plastic
    Weight –
    5V & 12V Input – 2.2g (0.08Oz)
    24V Input– 2.6g (0.09Oz)
    Tolerance Millimeters Inches
      X.X±0.25 X.XX±0.01
      X.XX±0.13 X.XXX±0.005
    Pin ±0.05 ±0.002
     
     
     
     
     
     
     
    Absolute Maximum Ratings
    Parameter Min. Max Units
    Input Surge Voltage (1000mS) 5VDC Input Models -0.7 9 VDC
    12VDC Input Models -0.7 18 VDC
    24VDC Input Models -0.7 30 VDC

    Lead Temperature
    (1.5mm from case for 10sec.)

    --- 260 °C
    Internal Power Dissipation --- 450 mW
    Exceeding the unit absolute maximum ratings could cause damage. These are not continuous operating ratings.
     
    General Characteristics
    Parameter Conditions Min. Typ. Max. Units
    Isolation Voltage 60 Seconds 3000 --- --- VDC
    Isolation Resistance 500VDC 10 --- ---
    Isolation Capacitance 100kHz, 1V --- 60 100 pF
    Switching Frequency   70 100 120 kHz
    MTBF MIL-HDBK-217F @25°C Ground Benign 2 --- --- MHrs
     
    Environmental Characteristics
    Parameter Conditions Min. Max. Units
    Operating Temperature Ambient -40 +85 °C
    Operating Temperature Case -40 +90 °C
    Storage Temperature -40 +125 °C
    Humidity --- 95 %
    Cooling Free-Air Convection
     
    Output Characteristics
    Parameter Conditions Min. Typ. Max Units
    Line Regulation

    For Vin
    Change of 1%

    --- ±1.2 ±1.5 %
    Load Regulation Io = 20% to 100% See Selection Guide %
    Ripple & Noise
    20MHz BW --- 65 100 mV P-P
    Short Circuit 0.5 Second Max.
     
     
    Maximum Capacitive Load

    Models by Output Voltage
    (Each Output on Duals)

    Singles Duals Units
    220 100 uF
     
         
    Derating Curve (3.3, 5 & ±5V Outputs)
     
    Notes :
    1. Specifications typical at Ta=+25°C, resistive load, nominal input voltage, rated output current unless otherwise noted.
    2. These power converters require a minimum output load to maintain specified regulation.
    3. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed.
    4. All DC/DC converters should be externally fused at the front end for protection.
    5. Other input and output voltage may be available, please contact factory
    6. All specifications subject to change without notice.
       
     
    Derating Curve (Other Outputs)
       
     